ADC Part No. 113125
For replacement parts, contact the reseller from which the dryer
was purchased or
American Dryer Corporation
88 Currant Road
Fall River MA 02720-4781
Telephone: (508) 678-9000 / Fax: (508) 678-9447
E-mail: techsupport@amdry.com
www.amdry.com
020200RF/pb
WARNING: For your safety the
information in this manual must be
followed to minimize the risk of fire or
explosion or to prevent property damage,
personal injury or death.
Do not store or use gasoline or other flammable
vapor and liquids in the vicinity of this or any
other appliance.
WHAT DO YOU DO IF YOU SMELL GAS
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Clear the room, building or area of all
occupants.
* Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Ne pas entreposer ni utiliser d’essence ni
d’autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
* Ne pas tenter d’allumer d’appareil.
* Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones se trouvant dans
le bâtiment où vous vous trouvez.
* Évacuez la pièce, le bâtiment ou la zone.
* Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
* Si vous ne pouvez rejoindre le fournisseur
de gaz, appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
ML-96D
Installation Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 42 43

Shrnutí obsahu

Strany 1 - Installation Manual

ADC Part No. 113125For replacement parts, contact the reseller from which the dryerwas purchased orAmerican Dryer Corporation88 Currant RoadFall River

Strany 2 - Important

6SECTION IISPECIFICATIONS/COMPONENT IDENTIFICATIONA. SPECIFICATIONSIMPORTANT: Dryer must be supplied with clean, dry, and regulated air pressure at 8

Strany 3 - FOR YOUR SAFETY

7NOTE: ADC reserves the right to make changes in specifications at any time without notice orobligation.SpecificationsML-96D

Strany 4

8B. COMPONENT IDENTIFICATION1. Dryer Front ViewIllus. No. Description1 Microprocessor Control/Keyboard (touch pad) Panel Assembly (controls)2 Control

Strany 5 - Table of Contents

9Illus. No. Description1 Electrical Service Connections2 Top Console3 Heating Unit4 Relay/Wiring Box5 Data Label and Installation Label6 Air Connectio

Strany 6

10SECTION IIIINSTALLATION PROCEDURESInstallation should be performed by competent technicians in accordance with local and state codes. In theabsence

Strany 7 - SECTION I

11B. UNPACKING/SETTING UPRemove protective shipping material (i.e., plastic wrap and optional shipping box) from dryer.IMPORTANT: Dryer must be trans

Strany 8 - B. SAFETY PRECAUTIONS

121. Leveling DryerTo level dryer, place 4-inch (10.16 cm) square metal shims (refer to the illustration on page 11) or othersuitable material under t

Strany 9

13C. DRYER ENCLOSURE REQUIREMENTSEven though a 30-inch (76.2 cm) clearance is acceptable, it is recommended that the rear of the dryer bepositioned

Strany 10 - SECTION II

14D. FRESH AIR SUPPLYWhen the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), andexhausts it out of

Strany 11 - Specifications

15E. EXHAUST REQUIREMENTS1. General Exhaust Ductwork InformationExhaust ductwork should be designed and installed by a qualified professional. Impro

Strany 12 - B. COMPONENT IDENTIFICATION

Retain This Manual In A Safe Place For Future ReferenceAmerican Dryer Corporation products embody advanced concepts in engineering, design, and safety

Strany 13

162. Single Dryer VentingWhere possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct shouldbe laid out in suc

Strany 14 - SECTION III

17IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only beincreased to an extent. Maximum proportional ductwork runs

Strany 15 - B. UNPACKING/SETTING UP

183. Multiple Dryer (common) VentingIf it is not feasible to provide separate exhaust ducts for each dryer, ducts from individual dryers may bechannel

Strany 16

19a. Outside Ductwork Protection1) To protect the outside end of horizontal ductwork from the weather, a 90º elbow bent downwardshould be installed wh

Strany 17

20Each dryer should be connected to an independently protected branch circuit. The dryer must be connectedwith copper wire only. DO NOT use aluminum

Strany 18 - D. FRESH AIR SUPPLY

213. GroundingA ground (earth) connection must be provided and installed in accordance with state and local codes. Inthe absence of these codes, grou

Strany 19 - E. EXHAUST REQUIREMENTS

22G. GAS INFORMATIONIt is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gasplumbing instal

Strany 20

232. Technical Gas Dataa. Gas Specificationsb. Gas ConnectionsInlet connection -----------1-inch N.P.T.Inlet supply size -----------1-inch N.P.T. (min

Strany 21

243. Piping and ConnectionsALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATESTEDITION, or in Canada, CAN

Strany 22

25Consistent gas pressure is essential at ALL gas connections. It is recommended that a 1-inch (2.54 cm)pipe gas loop be installed in the supply line

Strany 23 - F. ELECTRICAL INFORMATION

IMPORTANTYOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GASSUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINETO ALLOW ACCESS

Strany 24 - 460/480 3ø 3/4

266. Be sure ALL side and base panels are on the dryer.7. Check ALL service doors to insure that they are closed and secure.8. Be sure the lint drawer

Strany 25

273) Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap ofeach dryer to assure that the water column (W.C

Strany 26 - G. GAS INFORMATION

28NOTE: The dryer can be stopped at any time by opening main door or by pressing the "STOP" key.To restart the dryer, press the "START&

Strany 27 - TYPE OF GAS L.P

29SECTION IVSERVICE/PARTS INFORMATIONA. SERVICE1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If s

Strany 28

30SECTION VWARRANTY INFORMATIONA. RETURNING WARRANTY CARD(S)1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the ba

Strany 29

312. Each part must be tagged with the following information:a. Model number and serial number of the dryer from which part was removed.b. Nature of f

Strany 30 - I. PREOPERATIONAL TESTS

32SECTION VIROUTINE MAINTENANCEA. CLEANINGA program or schedule should be established for periodic inspection, cleaning, and removal of lint from var

Strany 31 - J. OPERATING INSTRUCTIONS

332. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.3. Clean any lint accumulation in and around both the bl

Strany 32 - K. SHUT DOWN INSTRUCTIONS

34SECTION VIIPROCEDURE FOR FUNCTIONAL CHECKOF REPLACEMENT COMPONENTS1. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760)Theor

Strany 33 - SECTION IV

352. For Direct Spark Ignition (DSI) System Models Manufactured With ADC Module Part No. 880815a. Upon completing installation of thereplacement DSI m

Strany 34 - SECTION V

WARNINGThe dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY or FIRE COULD RESULT.IMPOR

Strany 35

36SECTION VIIIDATA LABEL/LOCATION INFORMATIONA. DATA LABELContact American Dryer CorporationWhen contacting American Dryer Corporation certain infor

Strany 36 - SECTION VI

37THE DATA LABEL1. MODEL NUMBERThe model number is an ADC number, which describes the size of the dryer and thetype of heat (gas, electric, or steam).

Strany 37 - C. LUBRICATION

38SECTION IXBURNER and BASKET (TUMBLER)/LINT CHAMBERMANUAL RESET HI-LIMIT INSTRUCTIONS(FOR PHASE 6 MODELS)This dryer was manufactured with a burner ma

Strany 38 - SECTION VII

ADC 113125 1- 02/16/00-10 2- 12/08/00-10 3*03/09/01-25

Strany 39

Table of ContentsSECTION IIMPORTANT INFORMATION...3A. Receiving and Handli

Strany 40 - SECTION VIII

SECTION VIIPROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENTCOMPONENTS ...

Strany 41

3SECTION IIMPORTANT INFORMATIONA. RECEIVING and HANDLINGThe dryer is shipped in a protective stretch wrap cover with protective cardboard corners and

Strany 42 - SECTION IX

4B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk offire or explosion or to preve

Strany 43

57. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaustductwork, and inside the dryer. The freq

Komentáře k této Příručce